行業資訊
定安電梯維修保養人員的工作內容
隨著科技的進步,電梯技術水平不斷提高,其運行的可靠性明顯加大。在維修保養中,一些比較典型的停梯故障需要及時排出。
1、斷相引起停梯
當三相(xiang)(xiang)電(dian)(dian)(dian)源(yuan)(yuan)出(chu)(chu)現(xian)斷相(xiang)(xiang)時(shi),相(xiang)(xiang)序繼電(dian)(dian)(dian)器動(dong)作切(qie)斷a全回路,使電(dian)(dian)(dian)梯(ti)停止運行。這種故障多出(chu)(chu)在繼電(dian)(dian)(dian)器邏輯控制的電(dian)(dian)(dian)梯(ti),因為是老式電(dian)(dian)(dian)梯(ti),電(dian)(dian)(dian)源(yuan)(yuan)開關多為閘刀式,電(dian)(dian)(dian)源(yuan)(yuan)經過j限開關,再(zai)送至(zhi)電(dian)(dian)(dian)梯(ti)控制柜、電(dian)(dian)(dian)源(yuan)(yuan)流經的兩個開關,共六根(gen)保(bao)險絲。電(dian)(dian)(dian)梯(ti)運行、起動(dong),電(dian)(dian)(dian)流都很大。經過一段時(shi)間運行,如維保(bao)人員不及時(shi)檢查,保(bao)險絲與(yu)螺絲連(lian)接處(chu)易燒(shao)斷,電(dian)(dian)(dian)梯(ti)斷相(xiang)(xiang),引起停梯(ti),輕則關人,重則發(fa)生事故。
主要預防措施:
①保(bao)養人員要經常巡視檢(jian)查,發現(xian)可疑之處(chu),及(ji)時修(xiu)理,出現(xian)發燙、打火(huo)花諸類情形應立(li)即更(geng)換。
②建議用戶將閘刀開關更換為(wei)相當容量(liang)的空氣開關。
③現在(zai)設計的電梯(ti)都沒有電源j限開關,筆者認為(wei),可以就a全(quan)(quan)回(hui)路(lu)略作(zuo)改動,即(ji)加裝(zhuang)上、下j限電氣開關串聯在(zai)a全(quan)(quan)回(hui)路(lu)中,拆除原j限開關。
2、漲繩輪開關斷開引起停梯
像曳引繩(sheng)一樣,限速(su)器(qi)繩(sheng)同樣會(hui)在使用(yong)過(guo)程中伸長。由于底坑漲繩(sheng)輪重錘的作用(yong),漲繩(sheng)輪開關打板偏移,直(zhi)到斷開開關導致停(ting)梯(ti)。
對于電梯安裝的新裝電梯,電梯安裝人員須每月(yue)(yue)檢(jian)查(cha)一(yi)次(ci),運(yun)行一(yi)年(nian)以后,三個月(yue)(yue)檢(jian)查(cha)一(yi)次(ci),如此(ci)即(ji)可防(fang)患(huan)于(yu)(yu)未然。由(you)于(yu)(yu)廳門密封不嚴,井道有(you)(you)墻洞等各種(zhong)原因(yin),老鼠竄(cuan)入(ru)井道時有(you)(you)的(de)會(hui)摔死,有(you)(you)的(de)掉入(ru)底坑(keng)因(yin)想方設法(fa)逃出竄(cuan)入(ru)繩輪而(er)卡入(ru)其中,電梯向下(xia)運(yun)行導(dao)致(zhi)a全鉗(qian)開關(guan)動作,有(you)(you)的(de)限速(su)器開關(guan)也(ye)一(yi)起聯動。